Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 05/21/2024 17:49 |
Project Number: 0000001075 | Location: WORCHESTER REGIONAL ARPT, Massachusetts | ||||
Client Name: Jessica Ritsko Gas | Address: 33 LORCHRIS ST Leominster MA, 01453 | ||||
Job SIR: -0.4458 | Job Cost: $12,626.70 | Total Fuel Cost: $2.39 | Job Lifetime: 5.67 Years | ||
Annual Savings of -3.67 mmbtu | Lifetime Savings of -20.83 mmbtu | CFM50 Reduction: 570.24 | CFM: 19.76% | ||
Pre Heating Degree Days: 6,510.42 | Post Heating Degree Days: 6,510.42 | Pre Cooling Degree Days: 666.04 | Post Cooling Degree Days: 666.04 |
System Design Capacity | |||||
Item | Pre | Post | |||
Heating | |||||
Cooling | |||||
Peak Heating Load (BTU/Hr) | 100,405.45 | 100,405.45 | |||
Peak Cooling Load (BTU/Hr) | 41,475.54 | 41,475.54 | |||
Heating Output (BTU/Hr) | 62,500 | 62,500 | |||
Cooling Output (BTU/Hr) | 36,000 | 36,000 | |||
Heating Thermostat Setting | 68 | 68 | |||
Cooling Thermostat Setting | 78 | 78 | |||
Heating Design Temperature | 6 | 6 | |||
Cooling Design Temperature | 83 | 83 | |||
Tolerance | 0 | 0 | |||
Annual Heating Architectural Load (MMBTU) | 115.77 | 115.77 | |||
Annual Cooling Architectural Load (MMBTU) | 10.62 | 10.62 |
Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 05/21/2024 17:49 | |||||||||||||
Energy Saving Measures | |||||||||||||
Section | Pre-R | Post-R | Measure | Savings (mmbtu/year) | Savings (mmbtu/lifetime) | Net Cost | Adjusted Cost | SIR | Life Year | ||||
Natual Gas Furnace w/ECM Replace Con>=97% AFUE | --- | --- | Natual Gas Furnace w/ECM Replace Con>=97% AFUE | 8.15 | 81.53 | $9,000.00 | 0.17 | 10 | |||||
Domestic Hot Water | --- | --- | Delmei Handheld Showerhead Chrome (1.7 gpm) 3000.172 | 0.26 | 3.84 | $1,264.70 | 0.05 | 15 | |||||
Domestic Hot Water | --- | --- | Aerator Standard (1.5gpm) | 0.26 | 1.79 | $1,112.00 | 0.03 | 7 | |||||
Clothes Washer (Top Loader) | --- | --- | Clothes Washer (ENERGY STAR certified) | -12.34 | -108 | $1,200.00 | -6.06 | 10 | |||||
Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 05/21/2024 17:49 | |||||||||||||
Weatherization | |||||||||||||
Section | Pre-R | Post-R | Measure | Savings (mmbtu/year) | Savings (mmbtu/lifetime) | Net Cost | Adjusted Cost | SIR | Life Year | ||||
Natual Gas Furnace w/ECM Replace Con>=97% AFUE | --- | --- | Natual Gas Furnace w/ECM Replace Con>=97% AFUE | 8.15 | 81.53 | $9,000.00 | 0.17 | 10 | |||||
Other Measures included in SIR | |||||||||||||
Measure | Quantity | Unit Cost | Net Cost | ||||||||||
Advanced Power Strip: 7 Outlet | 1 | $50.00 | $50.00 | ||||||||||
Baseload (Annual & Lifetime Savings in Kwh) | |||||||||||||
Section | Measure | Annual Savings | Lifetime Savings | Net Cost | SIR | Life Year | |||||||
Clothes Washer (Top Loader) | Clothes Washer (ENERGY STAR certified) | -3,613.5 | -31,625.56 | $1,200.00 | -6.06 | 10 | |||||||
Domestic Hot Water (Annual & Lifetime Savings in CCF) | |||||||||||||
Measure | Annual Savings | Lifetime Savings | Net Cost | SIR | Life Year | ||||||||
Delmei Handheld Showerhead Chrome (1.7 gpm) 3000.172 | 2.56 | 38.42 | $1,264.70 | 0.05 | 15 | ||||||||
Aerator Standard (1.5gpm) | 2.56 | 17.93 | $1,112.00 | 0.03 | 7 | ||||||||
Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 05/21/2024 17:49 | |||||||||||||
System Fuel | |||||||||||||
System | Fuel Type | Modeled Pre-MMBTU | Modeled Post-MMBTU | Modeled Pre-Usage | Actual Reported Pre-Usage | Unit | Actual Reported Pre-MMBTU | Pre Usage Variance | Pre-Usage Ratio | Modeled Post-Usage | Pre-Cost | Post-Cost | Savings |
Heating | Natural Gas | 197.72 | 189.56 | 1,977.18 | 0.70 | CCF | 0.07 | 282,354.75% | 2,824.55 | 1,895.65 | $4,270.72 | $4,094.60 | $176.11 |
Hot Water | Natural Gas | 12.81 | 12.29 | 128.06 | 0.30 | CCF | 0.03 | 42,587.50% | 426.88 | 122.94 | $276.62 | $265.55 | $11.06 |
Baseload | Electric | 0.15 | 0.15 | 45.26 | 0.30 | Kwh | 0.00 | 14,986.68% | 150.87 | 45.26 | $10.41 | $10.41 | $0.00 |
Cooling | Electric | 12.20 | 12.20 | 3,571.79 | 0.70 | Kwh | 0.00 | 510,156.10% | 5,102.56 | 3,571.79 | $821.51 | $821.51 | $0.00 |
Total | 222.88 | 214.20 | 0.10 | 222,780.00% | 2,861.15 | ||||||||
Electric Usage Analysis | |||||
Type | System Name | Kwh Saving | Kw Saving | Peak Demand Reduction | Critical Peak Demand Reduction |
Cooling | Cooling System - Central Air | 0.00 | 0.00 | 0.00 | 0.00 |
Appliance | Clothes Washer (Top Loader) | -3,613.50 | 0.00 | 0.00 | 0.00 |
Hot Water | Hot Water | 0.00 | 0.00 | 0.00 | 0.00 |
Hot Water | Hot Water | 0.00 | 0.00 | 0.00 | 0.00 |
Total | -3,613.50 | 0.00 | 0.00 | 0.00 |
Energy Saving Report | ||||
Reporting UTC Date Time: 05/21/2024 17:49 | ||||
Consumption Section Loads (all in mmbtu) | ||||
Section | Heating Pre-Load | Heating Post-Load | Cooling Pre-Load | Cooling Post-Load |
Air Infiltration: Blower Door Test | 42.55 | 40.80 | 0.75 | 0.75 |
Attic Section: Unfloored (2X6 Unfloored Attic) | 8.12 | 7.79 | 0.14 | 0.14 |
Back Wall (2x4 Wall Finished w Vinyl Siding) | 30.66 | 29.40 | 2.50 | 2.50 |
Basement - Conditioned (Above Grade Wall) (Above Grade Wall) | 46.62 | 44.70 | 0.84 | 0.84 |
Basement - Conditioned (Basement Slab) (Basement Slab) | 0.45 | 0.43 | -0.01 | -0.01 |
Basement - Conditioned (Below Grade Basement Wall) (Below Grade Basement Wall) | 28.75 | 27.57 | -0.40 | -0.40 |
Basement - Conditioned (Sill Joist Conditioned Basement) (Sill Joist Conditioned Basement) | 7.39 | 7.09 | 0.13 | 0.13 |
Door - Thermal Insulated | 5.75 | 5.51 | 0.10 | 0.10 |
Front Wall (2x4 Wall Finished w Vinyl Siding) | 9.01 | 8.64 | 0.16 | 0.16 |
Left Wall (2x4 Wall Finished w Vinyl Siding) | 5.70 | 5.46 | 0.33 | 0.33 |
Right Wall (2x4 Wall Finished w Vinyl Siding) | 5.87 | 5.62 | 0.34 | 0.34 |
Windows - Double Pane Low-E | 16.58 | 15.90 | 2.68 | 2.68 |
Total | 207.45 | 198.91 | 7.56 | 7.56 |
Energy Saving Report | ||||
Reporting UTC Date Time: 05/21/2024 17:49 | ||||
Architectural Section Loads (all in mmbtu) | ||||
Section | Heating Pre-Load | Heating Post-Load | Cooling Pre-Load | Cooling Post-Load |
Air Infiltration: Blower Door Test | 23.75 | 23.75 | 1.05 | 1.05 |
Attic Section: Unfloored (2X6 Unfloored Attic) | 4.53 | 4.53 | 0.20 | 0.20 |
Back Wall (2x4 Wall Finished w Vinyl Siding) | 17.11 | 17.11 | 3.52 | 3.52 |
Basement - Conditioned (Above Grade Wall) (Above Grade Wall) | 26.01 | 26.01 | 1.19 | 1.19 |
Basement - Conditioned (Basement Slab) (Basement Slab) | 0.25 | 0.25 | -0.01 | -0.01 |
Basement - Conditioned (Below Grade Basement Wall) (Below Grade Basement Wall) | 16.05 | 16.05 | -0.57 | -0.57 |
Basement - Conditioned (Sill Joist Conditioned Basement) (Sill Joist Conditioned Basement) | 4.13 | 4.13 | 0.19 | 0.19 |
Door - Thermal Insulated | 3.21 | 3.21 | 0.14 | 0.14 |
Front Wall (2x4 Wall Finished w Vinyl Siding) | 5.03 | 5.03 | 0.22 | 0.22 |
Left Wall (2x4 Wall Finished w Vinyl Siding) | 3.18 | 3.18 | 0.46 | 0.46 |
Right Wall (2x4 Wall Finished w Vinyl Siding) | 3.27 | 3.27 | 0.47 | 0.47 |
Windows - Double Pane Low-E | 9.25 | 9.25 | 3.76 | 3.76 |
Total | 115.77 | 115.77 | 10.62 | 10.62 |
Energy Saving Report | ||||
Reporting UTC Date Time: 05/21/2024 17:49 | ||||
Section Solar Gain (all in mmbtu) | ||||
Section | Heating Pre-Load | Heating Post-Load | Cooling Pre-Load | Cooling Post-Load |
Attic Section: Unfloored (2X6 Unfloored Attic) | 0.00 | 0.00 | 0.00 | 0.00 |
Back Wall (2x4 Wall Finished w Vinyl Siding) | 2.27 | 2.27 | 2.66 | 2.66 |
Door - Thermal Insulated | 0.00 | 0.00 | 0.00 | 0.00 |
Front Wall (2x4 Wall Finished w Vinyl Siding) | 0.00 | 0.00 | 0.00 | 0.00 |
Left Wall (2x4 Wall Finished w Vinyl Siding) | 0.24 | 0.24 | 0.31 | 0.31 |
Right Wall (2x4 Wall Finished w Vinyl Siding) | 0.25 | 0.25 | 0.32 | 0.32 |
Windows - Double Pane Low-E | 2.68 | 2.68 | 3.23 | 3.23 |
Total | 5.44 | 5.44 | 6.52 | 6.52 |