Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06



Project Number: 0000001200 Location: WORCHESTER REGIONAL ARPT, Massachusetts
Client Name: RICHARD BRYANT Address: 27 BARTLETT ST Leominster MA, 01453
Job SIR: 29.9277 Job Cost: $12,066.84 Total Fuel Cost: $3,449.22 Job Lifetime: 11.75 Years
Annual Savings of 545.93 mmbtu Lifetime Savings of 6,415.89 mmbtu CFM50 Reduction: 1,214.70 CFM: 72.43%
Pre Heating Degree Days: 6,510.42 Post Heating Degree Days: 6,510.42 Pre Cooling Degree Days: 666.04 Post Cooling Degree Days: 666.04



Item Pre Post
Heating pennsylvaniapennsylvania pennsylvaniapennsylvania
Cooling pennsylvaniapennsylvania pennsylvaniapennsylvania
Peak Heating Load (BTU/Hr) 238,014.97 238,014.97
Peak Cooling Load (BTU/Hr) 40,175.77 39,282.07
Heating Output (BTU/Hr) 51,500 80,000
Cooling Output (BTU/Hr) 18,000 24,000
Heating Thermostat Setting 68 68
Cooling Thermostat Setting 78 78
Heating Design Temperature 6 6
Cooling Design Temperature 83 83
Tolerance 0 0
Annual Heating Architectural Load (MMBTU) 274.43 274.43
Annual Cooling Architectural Load (MMBTU) 14.09 14.09




Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06


Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Duct Distribution #1 --- --- 6 Hours Duct Sealing (>200ft uninsulated) 47.96 1,438.77 $1,370.84 49.32 30
(New) HVAC Heat Pump --- --- Air-to-Air Heat Pump Central (Fully displacing oil, propane, electric resistance, natural gas) 495.92 4,959.18 $10,046.00 29.10 10
Clothes Washer (Front Loader) --- --- Early Washer Replacement with ENERGY STAR 0.5 4.36 $150.00 1.96 10
Stovetop (Electric) --- --- Induction Stove Replacing NG 1.55 13.57 $500.00 1.83 10
 




Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06


Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Duct Distribution #1 --- --- 6 Hours Duct Sealing (>200ft uninsulated) 47.96 1,438.77 $1,370.84 49.32 30
(New) HVAC Heat Pump --- --- Air-to-Air Heat Pump Central (Fully displacing oil, propane, electric resistance, natural gas) 495.92 4,959.18 $10,046.00 29.10 10
 
Section Measure Annual Savings Lifetime Savings Net Cost SIR Life Year
Clothes Washer (Front Loader) Early Washer Replacement with ENERGY STAR 146 1,277.8 $150.00 1.96 10
Stovetop (Electric) Induction Stove Replacing NG 454.11 3,974.41 $500.00 1.83 10
 






Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06


System Fuel Type Modeled Pre-MMBTU Modeled Post-MMBTU Modeled Pre-Usage Actual Reported Pre-Usage Unit Actual Reported Pre-MMBTU Pre Usage Variance Pre-Usage Ratio Modeled Post-Usage Pre-Cost Post-Cost Savings
Heating Electric 705.30 138.69 206,528.63 6,274.06 Kwh 21.43 3,191.78% 32.92 40,612.72 $47,501.59 $9,340.93 $38,160.66
Cooling Electric 6.04 3.19 1,769.44 1,093.10 Kwh 3.73 61.87% 1.62 932.96 $406.97 $214.58 $192.39
Baseload Electric 5.67 3.62 1,660.68 5,016.26 Kwh 17.13 (66.89%) 0.33 1,060.56 $381.96 $243.93 $138.03
Total 717.01 145.50 42.29 1,595.46% 16.95
 


Type System Name Kwh Saving Kw Saving Peak Demand Reduction Critical Peak Demand Reduction
Heating Heating System - Furnace 0.00 0.00 0.00 0.00
Cooling Cooling System - Room A/C 0.00 0.00 0.00 0.00
Heat Pump (New) HVAC Heat Pump 145,217.48 0.00 0.00 0.00
Appliance Stovetop (Electric) 454.11 0.00 0.00 0.00
Appliance Clothes Washer (Front Loader) 146.00 0.00 0.00 0.00
Total 145,817.59 0.00 0.00 0.00


Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06


Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Air Infiltration: Blower Door Test 28.53 5.61 0.19 0.10
Attic Section: Kneewall (2x4 Unfloored Attic) 48.05 9.45 0.95 0.50
Door - Hollow Core 3.27 0.64 0.02 0.01
Floor - Dirt (Basement Dirt Floor) 113.06 22.23 0.74 0.39
Front Wall (2x2 Wall Asbestos) 513.76 101.03 3.35 1.77
Windows - Single Pane 2.51 0.49 0.10 0.05
Total 709.18 139.45 5.35 2.82


Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06


Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Air Infiltration: Blower Door Test 11.04 11.04 0.49 0.49
Attic Section: Kneewall (2x4 Unfloored Attic) 18.60 18.60 2.50 2.50
Door - Hollow Core 1.27 1.27 0.06 0.06
Floor - Dirt (Basement Dirt Floor) 43.75 43.75 1.94 1.94
Front Wall (2x2 Wall Asbestos) 198.80 198.80 8.83 8.83
Windows - Single Pane 0.97 0.97 0.27 0.27
Total 274.43 274.43 14.09 14.09


Energy Saving Report
Reporting UTC Date Time: 06/20/2024 07:06


Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attic Section: Kneewall (2x4 Unfloored Attic) 1.33 1.33 1.62 1.62
Door - Hollow Core 0.00 0.00 0.00 0.00
Front Wall (2x2 Wall Asbestos) 0.00 0.00 0.00 0.00
Windows - Single Pane 0.18 0.18 0.21 0.21
Total 1.51 1.51 1.83 1.83