Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 06/20/2024 07:06 |
Project Number: 0000001200 | Location: WORCHESTER REGIONAL ARPT, Massachusetts | ||||
Client Name: RICHARD BRYANT | Address: 27 BARTLETT ST Leominster MA, 01453 | ||||
Job SIR: 29.9277 | Job Cost: $12,066.84 | Total Fuel Cost: $3,449.22 | Job Lifetime: 11.75 Years | ||
Annual Savings of 545.93 mmbtu | Lifetime Savings of 6,415.89 mmbtu | CFM50 Reduction: 1,214.70 | CFM: 72.43% | ||
Pre Heating Degree Days: 6,510.42 | Post Heating Degree Days: 6,510.42 | Pre Cooling Degree Days: 666.04 | Post Cooling Degree Days: 666.04 |
System Design Capacity | |||||
Item | Pre | Post | |||
Heating | |||||
Cooling | |||||
Peak Heating Load (BTU/Hr) | 238,014.97 | 238,014.97 | |||
Peak Cooling Load (BTU/Hr) | 40,175.77 | 39,282.07 | |||
Heating Output (BTU/Hr) | 51,500 | 80,000 | |||
Cooling Output (BTU/Hr) | 18,000 | 24,000 | |||
Heating Thermostat Setting | 68 | 68 | |||
Cooling Thermostat Setting | 78 | 78 | |||
Heating Design Temperature | 6 | 6 | |||
Cooling Design Temperature | 83 | 83 | |||
Tolerance | 0 | 0 | |||
Annual Heating Architectural Load (MMBTU) | 274.43 | 274.43 | |||
Annual Cooling Architectural Load (MMBTU) | 14.09 | 14.09 |
Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 06/20/2024 07:06 | |||||||||||||
Energy Saving Measures | |||||||||||||
Section | Pre-R | Post-R | Measure | Savings (mmbtu/year) | Savings (mmbtu/lifetime) | Net Cost | Adjusted Cost | SIR | Life Year | ||||
Duct Distribution #1 | --- | --- | 6 Hours Duct Sealing (>200ft uninsulated) | 47.96 | 1,438.77 | $1,370.84 | 49.32 | 30 | |||||
(New) HVAC Heat Pump | --- | --- | Air-to-Air Heat Pump Central (Fully displacing oil, propane, electric resistance, natural gas) | 495.92 | 4,959.18 | $10,046.00 | 29.10 | 10 | |||||
Clothes Washer (Front Loader) | --- | --- | Early Washer Replacement with ENERGY STAR | 0.5 | 4.36 | $150.00 | 1.96 | 10 | |||||
Stovetop (Electric) | --- | --- | Induction Stove Replacing NG | 1.55 | 13.57 | $500.00 | 1.83 | 10 | |||||
Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 06/20/2024 07:06 | |||||||||||||
Weatherization | |||||||||||||
Section | Pre-R | Post-R | Measure | Savings (mmbtu/year) | Savings (mmbtu/lifetime) | Net Cost | Adjusted Cost | SIR | Life Year | ||||
Duct Distribution #1 | --- | --- | 6 Hours Duct Sealing (>200ft uninsulated) | 47.96 | 1,438.77 | $1,370.84 | 49.32 | 30 | |||||
(New) HVAC Heat Pump | --- | --- | Air-to-Air Heat Pump Central (Fully displacing oil, propane, electric resistance, natural gas) | 495.92 | 4,959.18 | $10,046.00 | 29.10 | 10 | |||||
Baseload (Annual & Lifetime Savings in Kwh) | |||||||||||||
Section | Measure | Annual Savings | Lifetime Savings | Net Cost | SIR | Life Year | |||||||
Clothes Washer (Front Loader) | Early Washer Replacement with ENERGY STAR | 146 | 1,277.8 | $150.00 | 1.96 | 10 | |||||||
Stovetop (Electric) | Induction Stove Replacing NG | 454.11 | 3,974.41 | $500.00 | 1.83 | 10 | |||||||
Energy Saving Report | |||||||||||||
Reporting UTC Date Time: 06/20/2024 07:06 | |||||||||||||
System Fuel | |||||||||||||
System | Fuel Type | Modeled Pre-MMBTU | Modeled Post-MMBTU | Modeled Pre-Usage | Actual Reported Pre-Usage | Unit | Actual Reported Pre-MMBTU | Pre Usage Variance | Pre-Usage Ratio | Modeled Post-Usage | Pre-Cost | Post-Cost | Savings |
Heating | Electric | 705.30 | 138.69 | 206,528.63 | 6,274.06 | Kwh | 21.43 | 3,191.78% | 32.92 | 40,612.72 | $47,501.59 | $9,340.93 | $38,160.66 |
Cooling | Electric | 6.04 | 3.19 | 1,769.44 | 1,093.10 | Kwh | 3.73 | 61.87% | 1.62 | 932.96 | $406.97 | $214.58 | $192.39 |
Baseload | Electric | 5.67 | 3.62 | 1,660.68 | 5,016.26 | Kwh | 17.13 | (66.89%) | 0.33 | 1,060.56 | $381.96 | $243.93 | $138.03 |
Total | 717.01 | 145.50 | 42.29 | 1,595.46% | 16.95 | ||||||||
Electric Usage Analysis | |||||
Type | System Name | Kwh Saving | Kw Saving | Peak Demand Reduction | Critical Peak Demand Reduction |
Heating | Heating System - Furnace | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Cooling System - Room A/C | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Pump | (New) HVAC Heat Pump | 145,217.48 | 0.00 | 0.00 | 0.00 |
Appliance | Stovetop (Electric) | 454.11 | 0.00 | 0.00 | 0.00 |
Appliance | Clothes Washer (Front Loader) | 146.00 | 0.00 | 0.00 | 0.00 |
Total | 145,817.59 | 0.00 | 0.00 | 0.00 |
Energy Saving Report | ||||
Reporting UTC Date Time: 06/20/2024 07:06 | ||||
Consumption Section Loads (all in mmbtu) | ||||
Section | Heating Pre-Load | Heating Post-Load | Cooling Pre-Load | Cooling Post-Load |
Air Infiltration: Blower Door Test | 28.53 | 5.61 | 0.19 | 0.10 |
Attic Section: Kneewall (2x4 Unfloored Attic) | 48.05 | 9.45 | 0.95 | 0.50 |
Door - Hollow Core | 3.27 | 0.64 | 0.02 | 0.01 |
Floor - Dirt (Basement Dirt Floor) | 113.06 | 22.23 | 0.74 | 0.39 |
Front Wall (2x2 Wall Asbestos) | 513.76 | 101.03 | 3.35 | 1.77 |
Windows - Single Pane | 2.51 | 0.49 | 0.10 | 0.05 |
Total | 709.18 | 139.45 | 5.35 | 2.82 |
Energy Saving Report | ||||
Reporting UTC Date Time: 06/20/2024 07:06 | ||||
Architectural Section Loads (all in mmbtu) | ||||
Section | Heating Pre-Load | Heating Post-Load | Cooling Pre-Load | Cooling Post-Load |
Air Infiltration: Blower Door Test | 11.04 | 11.04 | 0.49 | 0.49 |
Attic Section: Kneewall (2x4 Unfloored Attic) | 18.60 | 18.60 | 2.50 | 2.50 |
Door - Hollow Core | 1.27 | 1.27 | 0.06 | 0.06 |
Floor - Dirt (Basement Dirt Floor) | 43.75 | 43.75 | 1.94 | 1.94 |
Front Wall (2x2 Wall Asbestos) | 198.80 | 198.80 | 8.83 | 8.83 |
Windows - Single Pane | 0.97 | 0.97 | 0.27 | 0.27 |
Total | 274.43 | 274.43 | 14.09 | 14.09 |
Energy Saving Report | ||||
Reporting UTC Date Time: 06/20/2024 07:06 | ||||
Section Solar Gain (all in mmbtu) | ||||
Section | Heating Pre-Load | Heating Post-Load | Cooling Pre-Load | Cooling Post-Load |
Attic Section: Kneewall (2x4 Unfloored Attic) | 1.33 | 1.33 | 1.62 | 1.62 |
Door - Hollow Core | 0.00 | 0.00 | 0.00 | 0.00 |
Front Wall (2x2 Wall Asbestos) | 0.00 | 0.00 | 0.00 | 0.00 |
Windows - Single Pane | 0.18 | 0.18 | 0.21 | 0.21 |
Total | 1.51 | 1.51 | 1.83 | 1.83 |