Energy Saving Report
Reporting UTC Date Time: 05/25/2023 10:50

Project Number: Daryl Walker_001 Location: FRANKLIN, Pennsylvania
Job SIR: 0.7107 Job Cost: $1,076.30 Job Lifetime: 21.82 Years Annual Savings of 1.43 mmbtu Lifetime Savings of 31.11 mmbtu
Total Fuel Cost: $3,047.66 Pre Heating Degree Days: 6,247.92 Post Heating Degree Days: 6,247.92 Pre Cooling Degree Days: 707.08 Post Cooling Degree Days: 707.08

Item Pre Post
Heating
Cooling
Peak Heating Load (BTU/Hr) 58,407.93 57,311.02
Peak Cooling Load (BTU/Hr) 4,800.93 4,750.06
Heating Output (BTU/Hr) 84,000 84,000
Cooling Output (BTU/Hr) N/A N/A
Heating Thermostat Setting 68 68
Cooling Thermostat Setting 78 78
Heating Design Temperature 6 6
Cooling Design Temperature 82 82
Tolerance 0 0
Annual Heating Architectural Load (MMBTU) 63.12 61.93
Annual Cooling Architectural Load (MMBTU) 2.63 2.61
 
Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Domestic Hot Water --- --- (ECM) Water Heater - Install Blanket 0.17 2.22 $65.00 0.93 13
Simple Basement Floors Existing1 17.08 27.35 (ECM) Insulation - Install R-11 Fiberglass(Floor) 1.59 31.84 $861.30 $861.30 0.93 20
Lighting --- --- LED - 6.5W interior - 60W 0 0 $150.00 0 10
 
Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Simple Basement Floors Existing1 17.08 27.35 (ECM) Insulation - Install R-11 Fiberglass(Floor) 1.59 31.84 $861.30 $861.30 0.93 20
 
Section Measure Annual Savings Lifetime Savings Net Cost SIR Life Year
Lighting LED - 6.5W interior - 60W 0 0 $150.00 0 10
 
Measure Annual Savings Lifetime Savings Net Cost SIR Life Year
(ECM) Water Heater - Install Blanket 50 650 $65.00 0.93 13
 
System Fuel Type Modeled Pre-MMBTU Modeled Post-MMBTU Modeled Pre-Usage Actual Reported Pre-Usage Unit Actual Reported Pre-MMBTU Pre Usage Variance Pre-Usage Ratio Modeled Post-Usage Pre-Cost Post-Cost Savings
Heating Electric 83.30 81.70 24,391.27 4,482.40 kWh 15.31 444.16% 5.44 23,925.08 $2,683.04 $2,631.76 $51.28
Hot Water Electric 8.54 8.37 2,500.00 3,361.80 kWh 11.48 (25.64%) 0.74 2,450.00 $275.00 $269.50 $5.50
Baseload Electric 0.15 0.15 43.80 3,361.80 kWh 11.48 (98.70%) 0.01 43.80 $4.82 $4.82 $0.00
Total 91.99 90.22 38.27 140.37% 2.40
 
Type System Name Kwh Saving Kw Saving Peak Demand Reduction Critical Peak Demand Reduction
Heating Heating System 0.00 0.00 0.00 0.00
Lighting Lighting 0.00 0.00 0.00 0.00
Hot Water Hot Water 0.00 0.00 0.00 0.00
Total 0.00 0.00 0.00 0.00
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics (2x4 Unfloored Attic) 18.32 18.32 0.00 0.00
Blower Door Tests 52.31 52.31 0.00 0.00
Doors Existing 1.31 1.31 0.00 0.00
Simple Basement Floors Existing1 (Carpeted Floor) 4.24 2.65 0.00 0.00
Walls North (2x4 Wall Finished w Siding) 3.37 3.37 0.00 0.00
Walls South (2x4 Wall Finished w Siding) 5.21 5.21 0.00 0.00
Total 84.76 83.17 0.00 0.00
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics (2x4 Unfloored Attic) 13.64 13.64 1.38 1.38
Blower Door Tests 38.95 38.95 0.48 0.48
Doors Existing 0.98 0.98 0.01 0.01
Simple Basement Floors Existing1 (Carpeted Floor) 3.16 1.97 0.07 0.05
Walls North (2x4 Wall Finished w Siding) 2.51 2.51 0.03 0.03
Walls South (2x4 Wall Finished w Siding) 3.88 3.88 0.66 0.66
Total 63.12 61.93 2.63 2.61
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics (2x4 Unfloored Attic) 0.73 0.73 0.00 0.00
Doors Existing 0.00 0.00 0.00 0.00
Walls North (2x4 Wall Finished w Siding) 0.00 0.00 0.00 0.00
Walls South (2x4 Wall Finished w Siding) 0.36 0.36 0.00 0.00
Total 1.09 1.09 0.00 0.00