Energy Saving Report
Reporting UTC Date Time: 07/03/2023 12:43

Project Number: Hoang Test03_001 Location: BUTLER CO. (AWOS), Pennsylvania
Job SIR: 1.0477 Job Cost: $3,652.00 Job Lifetime: 29.08 Years Annual Savings of 0.08 mmbtu Lifetime Savings of 2.39 mmbtu
Total Fuel Cost: $10,920.00 Pre Heating Degree Days: 5,976.46 Post Heating Degree Days: 5,976.46 Pre Cooling Degree Days: 861.25 Post Cooling Degree Days: 861.25

Item Pre Post
Heating pennsylvaniapennsylvania pennsylvaniapennsylvania
Cooling pennsylvaniapennsylvania pennsylvaniapennsylvania
Peak Heating Load (BTU/Hr) 1,752.32 996.24
Peak Cooling Load (BTU/Hr) 405.97 277.94
Heating Output (BTU/Hr) 798 798
Cooling Output (BTU/Hr) 790 790
Heating Thermostat Setting 68 68
Cooling Thermostat Setting 78 78
Heating Design Temperature 9 9
Cooling Design Temperature 84 84
Tolerance 0 0
Annual Heating Architectural Load (MMBTU) 2 1.14
Annual Cooling Architectural Load (MMBTU) 0.16 0.11
 
Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Walls Existing 5.46 22.56 (ECM) Insulation - Install R-19 Fiberglass(Wall) 0.08 2.31 $1,252.00 $1,252.00 2.94 30
Doors Existing 0.50 3.95 (ECM) Door- Build Bulkhead Door / Z Door 0.01 0.08 $1,200.00 $1,200.00 0.12 15
Refrigerator --- --- (ECM) Replace refrigerator 21 CF, Top Freezer,Energy Star, White, No Icemaker 0 0 $1,200.00 0 15
 
Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Walls Existing 5.46 22.56 (ECM) Insulation - Install R-19 Fiberglass(Wall) 0.08 2.31 $1,252.00 $1,252.00 2.94 30
Doors Existing 0.50 3.95 (ECM) Door- Build Bulkhead Door / Z Door 0.01 0.08 $1,200.00 $1,200.00 0.12 15
 
Section Measure Annual Savings Lifetime Savings Net Cost SIR Life Year
Refrigerator (ECM) Replace refrigerator 21 CF, Top Freezer,Energy Star, White, No Icemaker 0 0 $1,200.00 0 15
 
System Fuel Type Modeled Pre-MMBTU Modeled Post-MMBTU Modeled Pre-Usage Actual Reported Pre-Usage Unit Actual Reported Pre-MMBTU Pre Usage Variance Pre-Usage Ratio Modeled Post-Usage Pre-Cost Post-Cost Savings
Heating Electric 0.17 0.09 49.12 586.60 Kwh 2.00 (91.63%) 0.08 27.63 $383.16 $215.55 $167.61
Cooling Electric 0.03 0.02 9.60 102.20 Kwh 0.35 (90.61%) 0.09 7.05 $74.88 $55.00 $19.88
Baseload Electric 0.05 0.05 15.40 469.00 Kwh 1.60 (96.72%) 0.03 15.40 $120.08 $120.08 $0.00
Total 0.25 0.16 3.95 (93.67%) 0.06
 
Type System Name Kwh Saving Kw Saving Peak Demand Reduction Critical Peak Demand Reduction
Heat Pump HVAC Systems Existing 0.00 0.00 0.00 0.00
Refrigerator Refrigerator 0.00 0.00 0.00 0.00
Total 0.00 0.00 0.00 0.00
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics Existing (2x6 Unfloored Attic) 0.03 0.03 0.01 0.01
Blower Door Tests 0.03 0.03 0.00 0.00
Doors Existing 0.01 0.00 0.00 0.00
Simple Basement Floors Existing (Above Grade Wall) 0.02 0.02 0.00 0.00
Walls Existing (2x6 Wall Finished w Siding) 0.09 0.02 0.01 0.00
Total 0.18 0.10 0.02 0.01
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics Existing (2x6 Unfloored Attic) 0.32 0.32 0.06 0.06
Blower Door Tests 0.34 0.34 0.02 0.02
Doors Existing 0.06 0.01 0.00 0.00
Simple Basement Floors Existing (Above Grade Wall) 0.21 0.21 0.01 0.01
Walls Existing (2x6 Wall Finished w Siding) 1.07 0.26 0.07 0.02
Total 2.00 1.14 0.16 0.11
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics Existing (2x6 Unfloored Attic) 0.03 0.03 0.04 0.04
Doors Existing 0.00 0.00 0.00 0.00
Walls Existing (2x6 Wall Finished w Siding) 0.00 0.00 0.00 0.00
Total 0.03 0.03 0.04 0.04