Energy Saving Report
Reporting UTC Date Time: 07/05/2023 10:04

Project Number: Lori Wagner_001 Location: FRANKLIN, Pennsylvania
Job SIR: 2.8126 Job Cost: $4,174.35 Job Lifetime: 27.55 Years Annual Savings of 22.91 mmbtu Lifetime Savings of 631 mmbtu
Total Fuel Cost: $3,047.66 Pre Heating Degree Days: 6,247.92 Post Heating Degree Days: 6,247.92 Pre Cooling Degree Days: 707.08 Post Cooling Degree Days: 707.08

Item Pre Post
Heating pennsylvaniapennsylvania pennsylvaniapennsylvania
Cooling pennsylvaniapennsylvania pennsylvaniapennsylvania
Peak Heating Load (BTU/Hr) 31,292.88 18,962.34
Peak Cooling Load (BTU/Hr) 7,611.85 5,953.43
Heating Output (BTU/Hr) 84,000 84,000
Cooling Output (BTU/Hr)
Heating Thermostat Setting 68 68
Cooling Thermostat Setting 78 78
Heating Design Temperature 6 6
Cooling Design Temperature 82 82
Tolerance 0 0
Annual Heating Architectural Load (MMBTU) 32.53 19.71
Annual Cooling Architectural Load (MMBTU) 3.62 2.84
 
Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Attics Existing 8.37 37.64 (ECM) Install R-30 Fiberglass(Attic) 17.44 523.12 $1,644.30 $1,644.30 5.8 30
Duct Distribution for HVAC Systems Heating --- 11.00 Duct Insulation R-11 Wrap 2.31 46.25 $823.20 1.14 20
Simple Basement Floors 17.08 27.35 (ECM) Insulation - Install R-11 Fiberglass(Floor) 3.02 60.46 $1,526.85 $1,526.85 0.81 20
Lighting(Lighting Other) --- --- LED - 6.5W interior - 60W 0.13 1.17 $180.00 0.21 10
 
Section Pre-R Post-R Measure Savings (mmbtu/year) Savings (mmbtu/lifetime) Net Cost Adjusted Cost SIR Life Year
Attics Existing 8.37 37.64 (ECM) Install R-30 Fiberglass(Attic) 17.44 523.12 $1,644.30 $1,644.30 5.8 30
Duct Distribution for HVAC Systems Heating --- 11.00 Duct Insulation R-11 Wrap 2.31 46.25 $823.20 1.14 20
Simple Basement Floors 17.08 27.35 (ECM) Insulation - Install R-11 Fiberglass(Floor) 3.02 60.46 $1,526.85 $1,526.85 0.81 20
 
Section Measure Annual Savings Lifetime Savings Net Cost SIR Life Year
Lighting(Lighting Other) LED - 6.5W interior - 60W 39.06 341.81 $180.00 0.21 10
 
System Fuel Type Modeled Pre-MMBTU Modeled Post-MMBTU Modeled Pre-Usage Actual Reported Pre-Usage Unit Actual Reported Pre-MMBTU Pre Usage Variance Pre-Usage Ratio Modeled Post-Usage Pre-Cost Post-Cost Savings
Heating Oil 50.95 28.17 366.52 500.00 Gal. #2 oil 69.50 (26.70%) 0.73 202.69 $1,330.48 $735.77 $594.72
Baseload Electric 4.49 4.35 1,314.00 7,844.20 Kwh 26.79 (83.25%) 0.17 1,274.95 $144.54 $140.24 $4.30
Total 55.44 32.52 96.29 (42.42%) 0.20
 
Type System Name Kwh Saving Kw Saving Peak Demand Reduction Critical Peak Demand Reduction
Lighting Lighting(Lighting Other) 39.06 0.00 0.00 39.06
Total 39.06 0.00 0.00 39.06
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics Existing (2x4 Unfloored Attic) 21.47 3.62 0.00 0.00
Blower Door Tests 12.32 11.47 0.00 0.00
Doors Existing 1.39 1.30 0.00 0.00
Simple Basement Floors (Carpeted Floor) 8.65 5.03 0.00 0.00
Walls North (2x4 Wall Finished w Siding) 3.57 3.33 0.00 0.00
Walls South (2x4 Wall Finished w Siding) 5.45 5.08 0.00 0.00
Total 52.85 29.83 0.00 0.00
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics Existing (2x4 Unfloored Attic) 13.21 2.39 2.04 1.35
Blower Door Tests 7.58 7.58 0.38 0.38
Doors Existing 0.86 0.86 0.04 0.04
Simple Basement Floors (Carpeted Floor) 5.32 3.32 0.26 0.17
Walls North (2x4 Wall Finished w Siding) 2.20 2.20 0.11 0.11
Walls South (2x4 Wall Finished w Siding) 3.36 3.36 0.79 0.79
Total 32.53 19.71 3.62 2.84
 
Section Heating Pre-Load Heating Post-Load Cooling Pre-Load Cooling Post-Load
Attics Existing (2x4 Unfloored Attic) 0.82 0.73 0.00 0.00
Doors Existing 0.00 0.00 0.00 0.00
Walls North (2x4 Wall Finished w Siding) 0.00 0.00 0.00 0.00
Walls South (2x4 Wall Finished w Siding) 0.36 0.36 0.00 0.00
Total 1.18 1.09 0.00 0.00